Pulsation Dampeners for A.O.D.D. Pumps Inventory Items
Please Phone 910-270-2737 | We have people not voicemail | Call toll free 1-888-326-7377
Fluid Flow Control Animations
Fluid Flow Control Animations
img
img
img

Dampeners for
A.O.D.D. Pumps


Flow Fluctuation
Figure


img

Plastic Dampener
Bladder Type


Application
Example


img

Plastic Dampener
PTFE Diaphragm


Flow Fluctuation
Smoothing


img

Stainless Dampener
PTFE Diaphragm


Cushion Pre-Fill
Pressure


img

Stainless Dampener
Elastomer Bladder


Stainless or
Plastic Wetted with
Elastomer Flex-Tube


img
img

 

 

 

A.O.D.D. Pump Plastic Pulsation Dampener with Elastomer Bladder

Air Operated Double Diaphragm Pump with Plastic Dampeners

Below 40psi (approx. 3 BarG) the pressure used to drive a liquid of more than 50 cP into a halt, back out again from a "T" piece, and leave pulsation in the system. If you want smooth flow below 40psi, or to be able to flush your system, then always use a FLOW-THROUGH two connection pulsation dampener

POLY PROP For MAXIMUM SAVINGS

Plastic Pulsation Dampeners

Plastic and Stainless Pulsation Dampeners Plastic Pulsation Dampener

A.O.D.D. Pump Plastic Pulsation Dampener with Elastomer Bladder Application Example

For Plastic & A.O.D.D. PUMP systems
PipeGuard Plastic & Air Operated Double ended Diaphragm pumps

Below 40psi (Approx.. 3BarG) the pressure used to drive a liquid of more than 50 cP into, to a halt, then back out again from a "T" piece, leave pulsation in the system. If you want smooth flow below 40 psi, or to be able to flush your system, then always use a FLOW-THORUGH two connection pulsation dampener .

PROBLEM:

An A.O.D.D. could not suck water treatment chemicals from the 10ft high (3 meters) plastic drum stillage because it was 70ft (30 meters) away.
TECH. Notes: It is not necessary to read the areas shaded in this color. The good thing about an A.O.D.D. is that it jumps straight up to a constant flow rate after each stroke reversal, giving you a pretty smooth discharge flow (if the air line is large enough). The down side is: that it is difficult to fill instantaneously on the suction side.

ANSWER:

PIPEGUARD a Below was fitted to the pump inlet. Loss of suction power was avoided by eliminating flow reversal within - out twice connection continuous flow configuration, standard choice of dampener type PiG-Plas/TW

Plastic Pulsation Dampeners

RESULTS:

The A.O.D.D.
1. Can now fill - and pump.
2. Pumps at twice the rate through possible.
3. Pipe shake and breakage has ceased.
A PIPEGUARD PLASTIC from PVC was installed item b on the pump outlet, and the chemicals can now be pushed also to a mixing tank 320 ft (say 100 Meters) away.
Many different chemicals are handled buy the one system because the inlet - outlet twin hole through flow, enables flushing.

If you do not need in-place flush-through, and wish to provide "T" pieces, use the extra connection for relief valve, system drain, or a gauge.

For the same benefits, plus the SAFETY of a METAL OUTER SHELL, please go to PIPEHUGGER LP.




Additional AODD Pump Pulsation Dampeners Information:
Pulsation Dampener | Pulsation Dampener Drawings | Pulsation Dampener Safety