Dampeners for A.O.D.D. Pumps Flow Fluctuation Figure Plastic Dampener Bladder Type Application Example Plastic Dampener PTFE Diaphragm Flow Fluctuation Smoothing Stainless Dampener PTFE Diaphragm Cushion Pre-Fill Pressure Stainless Dampener Elastomer Bladder Stainless or Plastic Wetted with Elastomer Flex-Tube
|
A.O.D.D. Pump Stainless Pulsation Dampener with PTFE DiaphragmPressure Pulse Dampener Interceptor installation for metering pump with horizontal connection.
Pulsation Dampener Cushion Pre-fill Pressure and InstallationFor volumetric flow fluctuation smoothing, 80% of line pressure. For best results: Keep the distance between flow smoother and pump to no more than 10 pipe internal diameters.
To ensure that neither air nor gas bubbles collect & cause the pump to loose prime, install with liquid connection at the top. For Suction Systems:for suction systems install SoG dampener with the liquid connection at the top. For optimum performance ensure a straight line from the pump connection the diaphragm in the dampener.
For the Discharge of Pumps with horizontal connections:for the discharge of pump with horizontal connections place the LP Flexorber on it's side
Click here for an animated assembly and cross section of a low pressure diaphragm type pulsation dampener.